Anca AMD2000 Series Manual do Utilizador Página 165

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 189
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 164
Technical Data
ANCA Motion DS619-0-00-0019 - Rev 0 165
12
12.6 Environmental Specifications
Catalogue Number
D2003-2S1-A
D2009-2S1
Attribute
Qualification
12.6.11 Storage
Ambient Temperature
-20 to +6 C
Relative Humidity
5 to 90%
12.6.12 Transport
Ambient Temperature
-20 to +65° C
Relative Humidity
90% at 40° C
Mechanical vibration
5.9m/s
2
maximum
12.6.13 Installation and Operation
Permissible Ambient Temperature at rated
continuous current I
aN
0 to +50° C
Maximum Ambient Temperature with de-rating
15
+55° C
Relative Humidity
5 to 85% non-condensing
Mechanical vibration
5.9 m/s2 maximum
Unusual environmental conditions
Not provided beyond 60146-1-1
Maximum installation/operating altitude (with respect
to mean sea level)
1000
12.6.14 Physical Characteristics
Degree of Protection
IP20 in accordance with 60529
Mounting position in Operation
Vertical
Device Weight
1.25kg
2kg
Height (mm)
206
182
Width (mm)
43
60
Depth (mm)
189
185
12.6.15 Cooling
Fan Cooled
No
Yes
Heat generation @ full rated continuous current
2
31 W
80 W
15
De-rating is applied to the maximum rated continuous current I
aN
from 100% at 50°C down
to 50% at 60°C
2
This amount of heat energy needs to be removed from the equipment cabinet to prevent overheating
Vista de página 164
1 2 ... 160 161 162 163 164 165 166 167 168 169 170 ... 188 189

Comentários a estes Manuais

Sem comentários